Shenzhen ZK Electric Technology Co., Ltd. cindy@zundrive.com +86-15920127268
Product Details
Place of Origin: Guangdong,China
Brand Name: ZK/ZUN
Certification: CE,ISO
Model Number: SU100
Payment & Shipping Terms
Minimum Order Quantity: 1pcs
Price: Negotiation
Packaging Details: Wooden case,Paper box
Delivery Time: 3-5work day
Payment Terms: T/T, Western Union,Paypal
Supply Ability: 6000pcs per months
Output Voltage: |
380VAC |
Input Voltage: |
250V DC To 750V DC Or 380V±15% AC |
Type: |
DC/AC Inverters |
Application: |
Solar Pumping Syatem |
Protection Grate: |
IP20 |
Efficiency: |
≥96% |
Output Frequency Range: |
G Type:0~600Hz |
Storage Temperature: |
-30 ~+60℃ |
Output Voltage: |
380VAC |
Input Voltage: |
250V DC To 750V DC Or 380V±15% AC |
Type: |
DC/AC Inverters |
Application: |
Solar Pumping Syatem |
Protection Grate: |
IP20 |
Efficiency: |
≥96% |
Output Frequency Range: |
G Type:0~600Hz |
Storage Temperature: |
-30 ~+60℃ |
350VDC To 750VDC Input Solar Vfd 0.75Kw To 110Kw Solar Water Pump Inverter For Submersible Pump
ZK SU100 series solar pumping inverter feature:
A.Sleep Function.
B.Low-frequency Protection Function.
C.Dry Run Protection.
D.Over-current Protection.
E.Minimum Power Protection.
F.Full Water Protection.
G.Alarm Recovery Mode: 0: automatic recovery; 1: manual recovery
Solar pumping system:
Specification and rated parameters
D1: General type:90V DC to 400V DC or 110V±15% AC, 50/60Hz |
D2: General type:150V DC to 450V DC or 220V±15% AC, 50/60Hz |
||
Inverter specification | Current (A) | Inverter | Current (A) |
specification | |||
SU100-D1-R75G-B | 7 | SU100-D2-R75G-B | 4 |
SU100-D1-1R5G-B | 10 | SU100-D2-1R5G-B | 7 |
SU100-D2-2R2G-B | 10 | ||
SU100-D2-004G-B | 16 | ||
D3: General type:250V DC to 750V DC or 380V±15% AC, 50/60Hz | T3: General type:350V DC to 750V DC or 380V±15% AC, 50/60Hz | ||
Inverter specification | Current (A) | Inverter specification | Current (A) |
SU100-D3-R75G-B | 3 | SU100-T3-037G | 75 |
SU100-D3-1R5G-B | 4 | SU100-T3-045G | 90 |
SU100-D3-2R2G-B | 6 | SU100-T3-055G | 110 |
SU100-D3-004G-B | 10 | SU100-T3-075G | 150 |
SU100-D3-5R5G-B | 13 | SU100-T3-090G | 180 |
SU100-D3-7R5G-B | 17 | SU100-T3-110G | 210 |
SU100-D3-011G-B | 25 | SU100-T3-132G | 250 |
SU100-D3-015G-B | 32 | SU100-T3-160G | 310 |
SU100-D3-018G-B | 38 | ||
SU100-D3-022G-B | 45 | ||
SU100-D3-030G | 60 |
Technology Specification
Item |
Specification |
|
Power input |
Voltage, frequency |
D1: 90V DC to 400V DC or 110V±15% AC, 50/60Hz |
D2:150V DC to 450V DC or 220V±15% AC, 50/60Hz |
||
D3: 250V DC to 750V DC or 380V±15% AC, 50/60Hz |
||
T3: 350V DC to 750V DC or 380V±15% AC, 50/60Hz |
||
Allowable fluctuations |
voltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2 required |
|
Power factor |
≥0.94(with DC reactor) |
|
Efficiency |
≥96% |
|
Output |
Output voltage |
Output under rated condition: 3 phase, 0~input voltage, inaccuracy<5% |
Output frequency range |
G type:0~600Hz |
|
Output frequency accuracy |
Max frequency ±0.5% |
|
Overload capacity |
G type: 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s |
|
Main control performance |
Motor control mode |
V/F without PG , VC without PG , VC with PG |
Speed control range |
Vector control without PG, rated load 1:100;Vector control with PG, rated load 1:1000; |
|
Steady speed accuracy |
VC without PG: ≤2% rated synchronized speed; |
|
VC with PG: ≤0.05% rated synchronized speed |
||
Starting torque |
VC without PG: when 0.5Hz, 150% rated torque; |
|
VC with PG: when 0Hz, 200% rated torque |
||
Torque response |
VC without PG: ≤20ms; |
|
VC with PG: ≤10ms. |
||
Frequency accuracy |
Digit setting: max frequency×±0.01%; |
|
Analog setting: max frequency×±0.2% |
||
Frequency resolution |
Digital setting: 0.01Hz; |
|
Analog setting: maximum frequency × 0.05% |
||
product basic functions |
DC braking capacity |
Starting frequency:0.00~50.00Hz; Braking time:0.0~60.0s; |
Braking current:0.0~150.0% rated current |
||
Torque boost capacity |
Auto torque upgrade 0.0%~100.0%; |
|
Manual torque upgrade 0.0%~30.0% |
||
V/F curve |
4 modes: one linearity torque characteristic curve ,one self-setting V/F curve mode, one drop torque characteristic curve (1.1- 2.0 powers),and square V/F curve mode. |
|
Acceleration/Deceleration curve |
2 modes: linear Acceleration/Deceleration and S curve Acceleration/Deceleration. |
|
4 sets of ACC/DEC, time unit 0.01s selectable, longest time: 650.00s. |
||
Rated output voltage |
Rely on power supply voltage compensate function, while motor rated voltage is 100%, set it at the range of 50-100%(output can not over input voltage). |
|
Voltage auto-adjustment |
While power supply voltage fluctuates, it can auto-keep constant output voltage. |
|
Auto energy-saving running |
While under V/F control mode, according to load situation, auto-optimize output voltage to save energy. |
|
Standard functions |
PID control, speed track, power off restart, jump frequency, upper/lower frequency limit control, program operation, multi- speed, RS485, analog output, frequency impulse output. |
|
Frequency setting channels |
Keyboard digital setting, keyboard potentiometer ,Analog voltage/current terminal AI1,AI2, Communication given and multi-channel terminal selection, Main and auxiliary channel combination, expansion card, supporting different modes switch. |
|
Feedback input channel |
Voltage/Current Terminal AI1, Voltage/Current Terminal AI12, Communication |
|
given, pulse input X5. |
||
Running command channel |
Operation panel given,external terminal given, communication given, expansion card given. |
|
Input command signal |
Start, stop, FWD/REV, JOG, multi-step speed, reset, ACC/DEC time selection, frequency given channel selection, exterior fault alarm. |
|
Protective function |
Overvoltage, under-voltage, current limit, over-current, overload, electric thermal relay, overheat, overvoltage stall, data protection, rapid speed protection, input/output phase failure protection. |
|
Environment |
Install place |
altitude ≤ 1000m,above 1000m down the rated amount, each increase of 100m down the rated mount of 1%;no condensation, ice ,rain, snow, hail; solar radiation below 700W/㎡, air pressure 70-106 kPa. |
Temperature, humidity |
-10 ~ + 50 ℃, derating above 40 ℃, maximum temperature 60 ℃ (no-load operation)5% to 95% RH (non-condensing) |
|
Vibration |
When 9~200Hz, 5.9m/s2(0.6g) |
|
Storage temperature |
-30 ~+60℃ |
|
Protection grade |
IP20 |
|
Cooling method |
Forced air cooling |
Input voltage, total power solar arrays selection
Input voltage, power solar arrays selection |
|||||||
Pumps model |
Inverter models |
Vmp |
Voc |
Total Power of solar arrays |
|||
110VAC pumps |
D1 |
110*1.41=155VDC |
190VDC |
≧ (1.3 to 2.0) rated power |
|||
220VAC pumps |
D2 |
220*1.41=310VDC |
372VDC |
||||
380VAC pumps |
D3(Max |
380*1.41=540VDC |
648VDC |
||||
480VAC pumps |
D5 ( Max |
480*1.41=677VDC |
812VDC |
Although solar pump inverter built in high efficiency MPPT tracking arithmetic, up to 99.6% MPPT efficiency, but also need to consider many factors of solar radiation. It is no certain rules to determine exactly how many piece solar panels exactly input for system. If the output frequency can’t get to 50Hz/60Hz, please consider to connect more solar panels
FAQ:
Q1:What is the payment terms?
100% T/T in advance for sample order. 50% T/T in advance, banlance 50% T/T before delivery for bulk order.
Q2 : What's the different between inverter and solar inverter?
Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accpet DC input, it more save power.
Q3:What is your main market?
Our brands are well known in Africa, Middle East, Southeast Asia and South America.
Q4 : How about the delivery time?
2-4 days for sample order;15-25 days for bulk order.
Q5:How about the quality of your products?
Our raw materials are purchased from qualified suppliers. And we have a strong quality control team to guarantee our products quality