Product Details
High Light:
Size:
315*235*253
Display:
LED+LCD
Protection Function:
Overload,overvoltage,overcurrent
Start Mode:
Automatically /manual
Input Voltage:
250-800VDC Or 380V Input
Output Voltage:
3phase 380V Output
Weight:
7KG
Rate Power:
11KW
Size:
315*235*253
Display:
LED+LCD
Protection Function:
Overload,overvoltage,overcurrent
Start Mode:
Automatically /manual
Input Voltage:
250-800VDC Or 380V Input
Output Voltage:
3phase 380V Output
Weight:
7KG
Rate Power:
11KW
Product Description

11Kw 15Hp Inverter 99.6% 380V Output High Mppt Vfd Solar Pump Inverter For Agricultural Irrigation

 

ZK SG600 Solar pumping system overview

 

The SG600 series solar pump inverter is a low voltage AC drive of 0.3 to 100KW above rating designed to operate with energy drawn from solar panel or photovoltaic cells (PV). The inverter is customized to operate in dual supply mode, so the grid connected supply is used in the absence of energy from PV cells. This drive functions with the latest in technology maximum power point tracking (MPPT) algorithm to derive maximum power from the PV cells at any instant. The inverter is specifically designed to meet the requirements of pump manufacturers and the original equipment manufacturers (OEM).

 

 

ZK Solar Pump Inverter Features

 

1.Low carbon economy.


2.In-built MPPT with high efficiency.


3.Pump specific protection.


4.Remote monitoring.


5.Best off grid solution.


6.Perfect stable frequency output.

 

7.Multiple pumps protection function, short circuit, phase missing, over current, over voltage...

 

8.Compatible with dual power input, AC grid and DC power supply input.

 

 

11Kw 15Hp Inverter 99.6% 380V Output High Mppt Vfd Solar Pump Inverter For Agricultural Irrigation 0

 

ZK SG600  solar pump inverter voltage range

 

Model Applicable for
pumps
Input DC
voltage
Over voltage
point
Under voltage
point
Suggest
Vmp
Suggest
Voc
SG600-2T For 200V AC 150V-450V 450V 100V 310VDC 380VDC
SG600-4T For 400V AC 250V– 800V 800V 200V 520VDC 650VDC

 

 

Technical Specification

 

Recommended MPPT voltage range Vmpp 131 to 350 VDC for 1S (80V to 350VDC input, 3PH 110 to 220VAC output)
Vmpp 280 to 375VDC for 2T ( 150V to 350VDC input, 3PH 220 to 240VAC output)
Vmpp 486 to 800 VDC for 4T ( 250V to 900VDC input, 3PH 380 to 460VAC output)
Recommended input voltage (Voc and Vmmp) Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps
Voc 355(VDC), Vmpp 310(VDC) for 2T model or 220V AC pumps
Voc 620(VDC), Vmpp 540(VDC) for 4T model or 380V AC pump
Motor type Control for permanent magnet servo motor and asynchronous motor pumps.
Input power DC power from solar arrays or AC grid power
Maximum DC power input 450VDC for 220-240VAC output /900VDC for 380-460VAC output
Rated output voltage 3-phase , 110V/160V/220V. 3-phase, 220V/240V/380V/460V/480V
Output frequency range 0~50/60Hz
MPPT efficiency 97%,
Ambient temperature range (G-type inverter with submersible pumps, and P type for general pumps.
Solar pump control special performance MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation,
dry run protection, low stop frequency protection, minimum power input, motor maximum
current protection, flow calculating, energy generated calculating
Protection function Phase loss protection, phase short circuit protection , ground to phase circuit protection , input
and output short circuit protection. Stall protection
Protection degree IP20, Air force cooling
Running mode MPPT , CVT, variable frequency mode
Altitude Below 1000m; above 1000m, derated 1% for every additional 100m.

 

Models and specification

 

SN Models Rate
current
Output voltage
( 3PH VAC)
Applicable for
pumps
MPPT
voltage
Mini type 2S series : 150 to 450 VDC or 220/240VAC input,Vmp 310V,Voc 380V
1 SG600-2S-0K7GB-M 3.8A 0-240VAC 0.75KW 260 to 375
2 SG600-2S-1K5GB-M 7A 0-240VAC 1.5KW 260 to 375
3 SG600-2S-2K2GB-M 9A 0-240VAC 2.2kw 260 to 375
General type: 2S, 150 to 450 VDC or 220/ 240VAC input,Vmp 310, Voc 380
4 SG600-2S-0K7GB 3.8A 220V/240V 0.75KW 260 to 375
5 SG600-2S-1K5GB 7A 220V/240V 1.5KW 260 to 375
6 SG600-2S-2K2GB 9A 220V/240V 2.2KW 260 to 375
7 SG600-2S-4K0GB 17A 220V/240V 4.0KW 260 to 375
General type: 4T, 250/350 to 800 VDC or 380/ 440VAC input, Vmp520, Voc650
8 SG600-4T-0K7GB 2.3A 380V-440V 0.75KW 486 to 750
9 SG600-4T-1K5GB 3.8A 380V-440V 1.5KW 486 to 750
10 SG600-4T-2K2GB 5.1A 380V-440V 2.2KW 486 to 750
11 SG600-4T-4K0GB 9A 380V-440V 4.0KW 486 to 750
12 SG600-4T-5K5GB 13A 380V-440V 5.5KW 486 to 750
13 SG600-4T-7K5GB 17A 380V-440V 7.5KW 486 to 750
14 SG600-4T-011GB 25A 380V-440V 11KW 486 to 750
15 SG600-4T-015GB 32A 380V-440V 15KW 486 to 750

 

 

Solar arrays selection table for inverter and pumps

 

Connecting solar panels in series to get enough voltage input, and then calculating how much strings for getting enough power. Take a solar panels Voc38VDC, Vmp 31VDC, 265W for exampling. Please check if enough DC voltage input for system, Voc and Vmp. If the input voltage is correct, the inverter will not work properly. If the output frequency is not high, lower than 50/60Hz even in good sunlight radiation, please check if enough solar panels have been connected. The total power should be at least bigger 1.3 times than of rated power of pumps