Shenzhen ZK Electric Technology Co., Ltd. cindy@zundrive.com +86-15920127268
Product Details
Place of Origin: Guangdong, China
Brand Name: ZK
Certification: CE IEC
Model Number: S100-2S-1.5GB
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: 70USD per unit
Packaging Details: Carton box with flim
Delivery Time: 3-7days
Payment Terms: T/T, L/C, Western Union
Supply Ability: 5000pcs per week
Name: |
Mini VFD |
Motor Type: |
AM And PMSM |
Control Mode: |
V/F Open/closs Loop |
Torque Response: |
±5% |
Frequency: |
0-400HZ |
V/F Curve: |
3 Mode |
Over Load: |
150% For 60s |
Application: |
Motor Speed Contro |
Name: |
Mini VFD |
Motor Type: |
AM And PMSM |
Control Mode: |
V/F Open/closs Loop |
Torque Response: |
±5% |
Frequency: |
0-400HZ |
V/F Curve: |
3 Mode |
Over Load: |
150% For 60s |
Application: |
Motor Speed Contro |
Items | Specification | |||
Control mode | Control mode | V/F control | Sensorless in open loop | Close loop vector control |
Starting torque | 0.5Hz 150% | 0.5Hz 180% | 0.00Hz 180% | |
Speed adjust range | 0: 50 | 1:100 | 1:1000 | |
Speed stabilizing precision |
±1% | ±0.1% | ±0.02% | |
Torque precision | NO | NO | ±5% | |
Motor type |
General induction motor permanent magnet synchronous motor (PMSM ) |
|||
Function design | Highest frequency |
General vector control :320Hz V/f control: 3200Hz |
||
frequency resolution |
Digital setting: 0.01Hz Analog setting:maximum×0.025% |
|||
Carrier frequency | 0.5K~16KHz, the carrier frequency can be adjusted by temperature automatically | |||
Frequency reference setting method | Digital of Control panel, analog AI1, AI2, potentiometer of control panel, UP/DN control, communication, PLC pulse frequency | |||
Acceleration./deceleration characteristic | Linear curve and S curve accel. /decel. mode, range of time: 0.0 to 65000S. | |||
V/F curve | 3 mode: linear, multiple points, N Power | |||
V/F separation | 2 times separation: totally separation, half separation | |||
DC braking |
DC braking frequency: 0.0 to 300Hz, DC braking current: 0.0% to 100% |
|||
Braking unit | Standard built in for up to 4T22G (22kw), optional built it for 4T30G~4T110G (30kw to 110kw), external built for above 4T160kw . | |||
Jog function | Job frequency range: 0.0 to 50.0Hz, the acceleration and deceleration time of Jog | |||
Configured PID function | Easy to perform pressure, flow, temperature close loop control. | |||
PLC multiple speed | To achieve 16 segment speed running through built in PLC or terminal control | |||
Common Dc bus | Multiple drives use one DC bus for energy balance. | |||
Auto voltage regulation (AVR) | Enable to keep output voltage constant when grid fluctuation | |||
Over load tolerance capability |
G type model: 150% rated current for 60s, 180% rated current for 3s, P type Model: 120% rated current for 60s, 150% rated current for 3s. |
|||
Stall protection control when over current, over voltage | Carry out limiting automation for running current, voltage to prevent over current, over voltage frequently | |||
Rapid current limit function | Minimize the IGBT module broken to protect the AC Drive, maximum reduce the over current fault. | |||
Torque limit and torque control |
"Excavator" characteristics , torque limit automatically during motor running. Torque control is available in close loop vector control mode.
|
|||
Features | Friendly interface | Display “Hello” when power on. | ||
Multiple function key JOG button | It can set for Forward Jog, reverse Jog, forward/reverse switch | |||
Timing control function | A total running time and total running time calculating | |||
2 group motor parameters | To achieve two motor switchover freely, control mode is selectable | |||
Motor over heat protection | Accepting motor temperature sensor signal input via AI1 terminals. | |||
Multiple kinds encoder * | Compatible collector PG, differential PG, and rotary transformer Encoder( resolver). | |||
Command source | Control panel, control terminals, series communication, switch freely. | |||
Frequency source | Digital setting, analog current/voltage, pulse setting, serial communication, main and auxiliary combination. | |||
Protection function | Short circuit detect when power on, input/output phase loss, over voltage, over current, under voltage, over heat, over load protection. | |||
Environment | Application site | Indoor, free of exposure to sunlight, no dusty, no corrosive, no inflammable gas, no oil and water vapor, and water dipping | ||
Altitude | Lower 1000m | |||
Environment temperature | -10℃~+40℃, power derated for 40~50℃, rated current derated 1% for 1℃ increasing. | |||
humidity | Less than 95%, no water condense. | |||
storage | -40~+70℃ | |||
IP degree | IP20 |