Shenzhen ZK Electric Technology Co., Ltd. cindy@zundrive.com +86-15920127268
Product Details
Place of Origin: China
Brand Name: ZK
Certification: IEC CE
Model Number: S100
Payment & Shipping Terms
Minimum Order Quantity: 1pcs
Price: 70usd to 5000usd
Packaging Details: paper cartons package
Delivery Time: 3-5 days
Payment Terms: T/T
Supply Ability: 5000pcs per month
AC Grid Input: |
220V/380V |
Power: |
0.75kw To 710kw |
Protection Function: |
Motor Protection, Over Current, Over Voltage, Phase Missing, Under Voltage, Low Speed, Shortcircuit |
Built Functions: |
Multple Speed, PLC, PID, S Curve, Engineer Saving |
Frequency Range: |
0-2000HZ |
Control Mode: |
VF, Vector Control |
AC Grid Input: |
220V/380V |
Power: |
0.75kw To 710kw |
Protection Function: |
Motor Protection, Over Current, Over Voltage, Phase Missing, Under Voltage, Low Speed, Shortcircuit |
Built Functions: |
Multple Speed, PLC, PID, S Curve, Engineer Saving |
Frequency Range: |
0-2000HZ |
Control Mode: |
VF, Vector Control |
S100 motor VFD variable speed drive frequency inverter for motor speed controll
S100 series is a high performance General Purpose Frequency Inverter with current vector control. It mostly used to control and adjust the speed and torque of the 3 phase induction motor and also PMSM. It adopts mature platform of software and hardware with a high level standard design.
Functional optimization, flexible application, stable performance, wide voltage range design. Match with RoHS standard, excellent EMC performance, high performance, high quality to make it more comfortable for using.
S100 adopts high performance VECTOR control technology, higher torque output in low speed. Good dynamic characteristics, super overload capacity to make it easy to meet the demands of variable applications.
Main characteristics:
Hardware design | Excellent performance | High stability | Easy using |
Optimized structural design with high level platform | Stability the speed, widen speed range | Long life design | Instantaneous stop constantly function |
IGBT module equipped with full inverter | High speed output in vector control mode, fast dynamic response | New technology platform,big allowance derate design | Over excitation protection |
Independent air duct design with good heat dissipation | Big torque in low speed,low torque impulse | Conformal coating PCB | V/F complete separation and half a separation |
High EMC performance,small external disturbance,lower harmonic output | Speed tracking in hardware and software | Qualified temperature test | Pump and fan energy saving |
CE,RoHS standard | Drive multiple motor type | Full protection function | Flexible terminal function |
High performance in auto tuning mode | Reliable thermal design | Built-in PID function |
Technical specification
Items | Specification | |||
Control mode | Control mode | V/F control | Sensorless in open loop | Close loop vector control |
Starting torque | 0.5Hz 150% | 0.5Hz 180% | 0.00Hz 180% | |
Speed adjust range | 0: 50 | 1:100 | 1:1000 | |
Speed stabilizing precision |
±1% | ±0.1% | ±0.02% | |
Torque precision | NO | NO | ±5% | |
Motor type |
General induction motor permanent magnet synchronous motor (PMSM ) |
|||
Function design | Highest frequency |
General vector control :320Hz V/f control: 3200Hz |
||
frequency resolution |
Digital setting: 0.01Hz Analog setting:maximum×0.025% |
|||
Carrier frequency | 0.5K~16KHz, the carrier frequency can be adjusted by temperature automatically | |||
Frequency reference setting method | Digital of Control panel, analog AI1, AI2, potentiometer of control panel, UP/DN control, communication, PLC pulse frequency | |||
Acceleration./deceleration characteristic | Linear curve and S curve accel. /decel. mode, range of time: 0.0 to 65000S. | |||
V/F curve | 3 mode: linear, multiple points, N Power | |||
V/F separation | 2 times separation: totally separation, half separation | |||
DC braking |
DC braking frequency: 0.0 to 300Hz, DC braking current: 0.0% to 100% |
|||
Braking unit | Standard built in for up to 4T22G (22kw), optional built it for 4T30G~4T110G (30kw to 110kw), external built for above 4T160kw . | |||
Jog function | Job frequency range: 0.0 to 50.0Hz, the acceleration and deceleration time of Jog | |||
Configured PID function | Easy to perform pressure, flow, temperature close loop control. | |||
PLC multiple speed | To achieve 16 segment speed running through built in PLC or terminal control | |||
Common Dc bus | Multiple drives use one DC bus for energy balance. | |||
Auto voltage regulation (AVR) | Enable to keep output voltage constant when grid fluctuation | |||
Over load tolerance capability |
G type model: 150% rated current for 60s, 180% rated current for 3s, P type Model: 120% rated current for 60s, 150% rated current for 3s. |
|||
Stall protection control when over current, over voltage | Carry out limiting automation for running current, voltage to prevent over current, over voltage frequently | |||
Rapid current limit function | Minimize the IGBT module broken to protect the AC Drive, maximum reduce the over current fault. | |||
Torque limit and torque control |
"Excavator" characteristics , torque limit automatically during motor running. Torque control is available in close loop vector control mode.
|
|||
Features | Friendly interface | Display “Hello” when power on. | ||
Multiple function key JOG button | It can set for Forward Jog, reverse Jog, forward/reverse switch | |||
Timing control function | A total running time and total running time calculating | |||
2 group motor parameters | To achieve two motor switchover freely, control mode is selectable | |||
Motor over heat protection | Accepting motor temperature sensor signal input via AI1 terminals. | |||
Multiple kinds encoder * | Compatible collector PG, differential PG, and rotary transformer Encoder( resolver). | |||
Command source | Control panel, control terminals, series communication, switch freely. | |||
Frequency source | Digital setting, analog current/voltage, pulse setting, serial communication, main and auxiliary combination. | |||
Protection function | Short circuit detect when power on, input/output phase loss, over voltage, over current, under voltage, over heat, over load protection. | |||
Environment | Application site | Indoor, free of exposure to sunlight, no dusty, no corrosive, no inflammable gas, no oil and water vapor, and water dipping | ||
Altitude | Lower 1000m | |||
Environment temperature | -10℃~+40℃, power derated for 40~50℃, rated current derated 1% for 1℃ increasing. | |||
humidity | Less than 95%, no water condense. | |||
storage | -40~+70℃ | |||
IP degree | IP20 |
Three-phase 380v±20%, 50/60Hz
Model | Power capacity (KVA) | Input current(A) | Output current(A) | Adaptable motor(KW) |
S100-4T-0.7GB | 1.5 | 3.4 | 2.1 | 0.75 |
S100-4T-1.5GB | 3 | 5 | 3.8 | 1.5 |
S100-4T-2.2GB | 4 | 5.8 | 5.1 | 2.2 |
S100-4T-4.0G/5.5PB | 5.9 | 10.5 | 9 | 3.7 |
S100-4T-5.5G/7.5PB | 8.9 | 14.6 | 13 | 5.5 |
S100T-4T-7.5G/11PB | 11 | 20.5 | 17 | 7.5 |
S100-4T-11G/15PB | 17 | 26 | 25 | 11 |
S100-4T-15G/18.5PB | 21 | 35 | 32 | 15 |
S100-4T-18.5G/22PB | 24 | 38.5 | 37 | 18.5 |
S100-4T-22G/30PB | 30 | 46.5 | 45 | 22 |
S100-4T-30G/37P | 40 | 62 | 60 | 30 |
S100-4T-37G/45P | 57 | 76 | 75 | 37 |
S100-4T-45G/55P | 69 | 92 | 91 | 45 |
S100-4T-55G/75P | 85 | 113 | 112 | 55 |
S100-4T-75G/90P | 110 | 153 | 150 | 75 |
S100-4T-90G/110P | 130 | 182 | 180 | 90 |
S100-4T-110G/132P | 160 | 214 | 210 | 110 |
S100-4T-132G/160P | 192 | 232 | 253 | 132 |
S100-4T-160G/185P | 200 | 290 | 304 | 160 |
S100-4T-185G/200P | 220 | 330 | 340 | 185 |
S100-4T-200G/220P | 250 | 360 | 380 | 200 |
S100-4T-220G/250P | 280 | 385 | 426 | 220 |
S100-4T-250G/280P | 355 | 437 | 470 | 250 |
S100-4T-280G/315P | 396 | 498 | 530 | 280 |
S100-4T-315G/355P | 455 | 586 | 600 | 315 |
S100-4T-355G/400P | 500 | 624 | 660 | 355 |
S100-4T-400G/450P | 560 | 680 | 690 | 400 |
S100-4T-450G/500P | 630 | 755 | 770 | 450 |
S100-4T-500G/560P | 700 | 840 | 860 | 500 |
INFINEON IGBT using Using the latest generation of INFINEON/Fuji brand which is the best choose for inverter application
|
Stronger protection All-around test the components and temperature rise Output ground short circuit protection, relay (contactor) actuation fault protection, brake circuit over current, brake tube over load etc protection to improve the system security |
Conformal coating with reliability and stabilization Professional design with three proofing coatingprocess,good EMC performance |
Optimizing hardware design to reduce the fault PCB board 4 layer design to reduce “fly” wire and improve stability. 3 current sensor enhance the output protection. |
|
|
Longer life running Quality components using to guarantee the inverter to have a longer life for work |
Wide voltage design Full consideration of the grid voltage fluctuation and unbalance |