• 220V 2.2KW 3HP 10A solar VFD solar pump inverter for AM PMSM
220V 2.2KW 3HP 10A solar VFD solar pump inverter for AM PMSM

220V 2.2KW 3HP 10A solar VFD solar pump inverter for AM PMSM

Product Details:

Place of Origin: China
Brand Name: ZK ZUN
Certification: CE IEC
Model Number: SG600-2K2GB-2S

Payment & Shipping Terms:

Minimum Order Quantity: 1 Piece
Price: USD 78-120 per piece
Packaging Details: Carton box with flim
Delivery Time: 3-8days
Payment Terms: T/T, L/C, Western Union,, L/C
Supply Ability: 2000pcs per week
Get Best Price Contact Now

Detail Information

Product: Solar Pump VFD MPPT Efficiency: More Than 99%
Input Power: 90-450VDC Or 220VAC (Accept 110V) Output Power: 1/3PHASE 0-220VAC
Motor Type: AM And PMSM Pump Start Mode: Automatic And Manual
OEM: Avaliable Application: Solar Water Pump Project
High Light:

3HP 10A VFD solar pump inverter

,

AM PMSM 2.2KW VFD solar pump inverter

Product Description

220V 2.2KW 3HP 10A solar VFD solar pump inverter for AM PMSM
 
ZK SG600 solar water pump Inverter drives well all kind of AC pump in solar pumping system, including AM and PMSM:

 

  • MPPT with fast response speed, efficiency more than 99%;

  • Drives well all 1/3 phase AC pumps and PMSM high efficiency pumps.

  • The working voltage of solar panel can set by manual or MPPT automatic detect.

  • Grid AC and Solar DC power supply input at same time.

  • Built in automatic sleep-wake up function,

  • Dry run (under load ) protection

  • Motor maximum current protection

  • Low input power protection

  • Lowest stop frequency protection

  • The PQ (power/flow) performance curve enables calculating the flow output from the pump

  • Digital control for fully automatic operation, data storage and protective functions

  • Intelligent power module (IPM) for the main circuit

  • LED display, LCD diaplay is optional.

  • Low water probe sensor, and water level control function

  • Ambient temperature for using: -10 to +50˚C.

Solar panles Input voltage and power selection:

 

Input voltage, power solar arrays selection
Pumps model Inverte models Vmp Voc Total Power of solar arrays
110VAC pumps 1S 110*1.41=130VDC 156VDC

≧ (1.3 to 2.0) rated power of pumps.

The bigger total power input, the better result

220VAC pumps 2S 220*1.41=310VDC 372VDC
380VAC pumps 4T (Max 800VDC) 380*1.41=540VDC 648VDC
480VAC pumps 4T ( Max 900VDC) 480*1.41=677VDC 812VDC
 

Date sheet:

 

Specification of Solar pump inverter specification when parameters H9.00 set to for 1.
Recommended MPPT voltage range

Vmp 260 to 355VDC for 2S( For driving 220VAC pumps )

Vmp 486 to 650 VDC for 4T(For driving 380VAC pumps)

Recommended input Voc and Vmpp voltage

Voc 355(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps

Voc 620(VDC), Vmpp 540(VDC) for 4T model or 380V AC pumps

Motor(pump) type Control for permanent magnet synchronous motor (PMSM )and asynchronous motor pumps ( all type 3 phase induction motor)
Rated output voltage 3-Phase,110V/160V/220V. 3-phase, 220V/380V/460V
Output frequency range 0~Maximum frequency 400Hz.
Efficiency 99% to 99.6%
Over load capacity

G type for submersible pumps, 150% rated current for 60s, 180% rated current for 3s

P type for surface pump, 120% rated current for 60s, 150% rated current for 2s.

Solar pump control special performance MPPT ( maximum power point tracking),auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating and water tank level detected.
Protection function Phase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection, lightning protection, over heat protection.
Protection degree IP20, Air force cooling
Running mode MPPT or CVT
Altitude Below 1000m; above 1000m, derated 1% for every additional 100m.

Standard

AC input backup circuit

CE, Design based on AD800 series high performance inverter, more specification please refer to AD800 series vector control inverter operation manual


 
Solar DC and Grid AC can be input at same time.
GPRS remote controller is optional, can monitor and control the solar pump inverter  by Web or Mobile APP.
 
 
220V 2.2KW 3HP 10A solar VFD solar pump inverter for AM PMSM 0
 
FAQ:
 
Q1 : What is the solar pump Inverter?
ZK Solar pump inverter drives well all kind of AC pump including single phase pump and PMSM in solar pumping system, solar DC and Grid AC can be at same time. MPPT efficiency more than 99%.
 
Q2: What should be noticed when installing inverter?
Put the Inverter in a place where is well ventilate, cool, dry and water-proof. long-services life.


Q3: Do we need to set the parameter before using ?

Our inverter is AI intelligent working, can auto tracking the DC working voltage.
You can set parameters if you want other functions like Dry run, full tank detect.
 
Q4:Where is your factory located?
Our factory is located in Shenzhen, China, most welcome to visit us. We can pick up you from the Shenzhen Airport or High Speed Rail Station to our factory.
 
Q5:What is the supply capacity of your factory?
9000pcs inverters can be produced every month.
Export 7000-9000pcs inverters every month, to Thailand, India, Pakistan, the Middle East like Syria, Saudi, Yemen, Turkey, Egypt, Morocco... All African and South America like Mexico, Brazil.
Sample delivery time around 3-5days, bulk order around 10-30 days.
OEM & ODM services is avaliable.

 

Want to Know more details about this product
I am interested in 220V 2.2KW 3HP 10A solar VFD solar pump inverter for AM PMSM could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.